Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
MMWR Morb Mortal Wkly Rep ; 73(4): 77-83, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300853

RESUMO

On September 12, 2023, CDC's Advisory Committee on Immunization Practices recommended updated 2023-2024 (updated) COVID-19 vaccination with a monovalent XBB.1.5-derived vaccine for all persons aged ≥6 months to prevent COVID-19, including severe disease. During fall 2023, XBB lineages co-circulated with JN.1, an Omicron BA.2.86 lineage that emerged in September 2023. These variants have amino acid substitutions that might increase escape from neutralizing antibodies. XBB lineages predominated through December 2023, when JN.1 became predominant in the United States. Reduction or failure of spike gene (S-gene) amplification (i.e., S-gene target failure [SGTF]) in real-time reverse transcription-polymerase chain reaction testing is a time-dependent, proxy indicator of JN.1 infection. Data from the Increasing Community Access to Testing SARS-CoV-2 pharmacy testing program were analyzed to estimate updated COVID-19 vaccine effectiveness (VE) (i.e., receipt versus no receipt of updated vaccination) against symptomatic SARS-CoV-2 infection, including by SGTF result. Among 9,222 total eligible tests, overall VE among adults aged ≥18 years was 54% (95% CI = 46%-60%) at a median of 52 days after vaccination. Among 2,199 tests performed at a laboratory with SGTF testing, VE 60-119 days after vaccination was 49% (95% CI = 19%-68%) among tests exhibiting SGTF and 60% (95% CI = 35%-75%) among tests without SGTF. Updated COVID-19 vaccines provide protection against symptomatic infection, including against currently circulating lineages. CDC will continue monitoring VE, including for expected waning and against severe disease. All persons aged ≥6 months should receive an updated COVID-19 vaccine dose.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Estados Unidos/epidemiologia , Adulto , Humanos , Adolescente , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Eficácia de Vacinas , SARS-CoV-2
2.
MMWR Morb Mortal Wkly Rep ; 72(5): 119-124, 2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36730051

RESUMO

The SARS-CoV-2 Omicron sublineage XBB was first detected in the United States in August 2022.* XBB together with a sublineage, XBB.1.5, accounted for >50% of sequenced lineages in the Northeast by December 31, 2022, and 52% of sequenced lineages nationwide as of January 21, 2023. COVID-19 vaccine effectiveness (VE) can vary by SARS-CoV-2 variant; reduced VE has been observed against some variants, although this is dependent on the health outcome of interest. The goal of the U.S. COVID-19 vaccination program is to prevent severe disease, including hospitalization and death (1); however, VE against symptomatic infection can provide useful insight into vaccine protection against emerging variants in advance of VE estimates against more severe disease. Data from the Increasing Community Access to Testing (ICATT) national pharmacy program for SARS-CoV-2 testing were analyzed to estimate VE of updated (bivalent) mRNA COVID-19 vaccines against symptomatic infection caused by BA.5-related and XBB/XBB.1.5-related sublineages among immunocompetent adults during December 1, 2022­January 13, 2023. Reduction or failure of spike gene (S-gene) amplification (SGTF) in real-time reverse transcription­polymerase chain reaction (RT-PCR) was used as a proxy indicator of infection with likely BA.5-related sublineages and S-gene target presence (SGTP) of infection with likely XBB/XBB.1.5-related sublineages (2). Among 29,175 nucleic acid amplification tests (NAATs) with SGTF or SGTP results available from adults who had previously received 2­4 monovalent COVID-19 vaccine doses, the relative VE of a bivalent booster dose given 2­3 months earlier compared with no bivalent booster in persons aged 18­49 years was 52% against symptomatic BA.5 infection and 48% against symptomatic XBB/XBB.1.5 infection. As new SARS-CoV-2 variants emerge, continued vaccine effectiveness monitoring is important. Bivalent vaccines appear to provide additional protection against symptomatic BA.5-related sublineage and XBB/XBB.1.5-related sublineage infections in persons who had previously received 2, 3, or 4 monovalent vaccine doses. All persons should stay up to date with recommended COVID-19 vaccines, including receiving a bivalent booster dose when they are eligible.


Assuntos
COVID-19 , Adulto , Estados Unidos/epidemiologia , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , SARS-CoV-2/genética , Vacinas Combinadas , Teste para COVID-19 , Eficácia de Vacinas , RNA Mensageiro
3.
MMWR Morb Mortal Wkly Rep ; 72(7): 177-182, 2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36795625

RESUMO

On June 18, 2022, the Advisory Committee on Immunization Practices (ACIP) issued interim recommendations for use of the 2-dose monovalent Moderna COVID-19 vaccine as a primary series for children aged 6 months-5 years* and the 3-dose monovalent Pfizer-BioNTech COVID-19 vaccine as a primary series for children aged 6 months-4 years,† based on safety, immunobridging, and limited efficacy data from clinical trials (1-3). Monovalent mRNA vaccine effectiveness (VE) against symptomatic SARS-CoV-2 infection was evaluated using the Increasing Community Access to Testing (ICATT) program, which provides SARS-CoV-2 testing to persons aged ≥3 years at pharmacy and community-based testing sites nationwide§ (4,5). Among children aged 3-5 years with one or more COVID-19-like illness symptoms¶ for whom a nucleic acid amplification test (NAAT) was performed during August 1, 2022-February 5, 2023, VE of 2 monovalent Moderna doses (complete primary series) against symptomatic infection was 60% (95% CI = 49% to 68%) 2 weeks-2 months after receipt of the second dose and 36% (95% CI = 15% to 52%) 3-4 months after receipt of the second dose. Among symptomatic children aged 3-4 years with NAATs performed during September 19, 2022-February 5, 2023, VE of 3 monovalent Pfizer-BioNTech doses (complete primary series) against symptomatic infection was 31% (95% CI = 7% to 49%) 2 weeks-4 months after receipt of the third dose; statistical power was not sufficient to estimate VE stratified by time since receipt of the third dose. Complete monovalent Moderna and Pfizer-BioNTech primary series vaccination provides protection for children aged 3-5 and 3-4 years, respectively, against symptomatic infection for at least the first 4 months after vaccination. CDC expanded recommendations for use of updated bivalent vaccines to children aged ≥6 months on December 9, 2022 (6), which might provide increased protection against currently circulating SARS-CoV-2 variants (7,8). Children should stay up to date with recommended COVID-19 vaccines, including completing the primary series; those who are eligible should receive a bivalent vaccine dose.


Assuntos
COVID-19 , Criança , Estados Unidos/epidemiologia , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , SARS-CoV-2 , Vacina BNT162 , Vacinas contra COVID-19 , Vacina de mRNA-1273 contra 2019-nCoV , Teste para COVID-19 , Vacinas de mRNA , Vacinas Combinadas
4.
Am J Health Promot ; 37(2): 228-232, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36007095

RESUMO

PURPOSE: Information on incentives for COVID-19 testing is needed to understand effective practices that encourage testing uptake. We describe characteristics of those who received an incentive after performing a rapid antigen test. DESIGN: Cross-sectional descriptive analysis of survey data. SETTING: During April 29-May 9, 2021, COVID-19 rapid antigen testing was offered in 2 Maryland cities. SAMPLE: Convenience sample of 553 adults (≥18 years) who tested and received an incentive; 93% consented to survey. MEASURES: Survey questions assessed reasons for testing, testing history, barriers, and demographics. ANALYSIS: Robust Poisson regressions were used to determine characteristic differences based on testing history and between participants who would re-test in the future without an incentive vs participants who would not. RESULTS: The most common reasons for testing were the desire to be tested (n = 280; 54%) and convenience of location (n = 146; 28%). Those motivated by an incentive to test (n = 110; 21%) were 5.83 times as likely to state they would not test again without an incentive, compared to those with other reasons for testing (95% CI: 2.67-12.72, P < .001). CRITICAL LIMITATIONS: No comparative study group. CONCLUSION: Results indicate internal motivation and convenience were prominent factors supporting testing uptake. Incentives may increase community testing participation, particularly among people who have never tested. Keywords COVID-19, pandemic, incentives, health behavior, community testing.


Assuntos
COVID-19 , Motivação , Adulto , Humanos , Maryland , Teste para COVID-19 , Estudos Transversais , COVID-19/diagnóstico
5.
MMWR Morb Mortal Wkly Rep ; 71(48): 1526-1530, 2022 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-36454688

RESUMO

On September 1, 2022, bivalent COVID-19 mRNA vaccines, composed of components from the SARS-CoV-2 ancestral and Omicron BA.4/BA.5 strains, were recommended by the Advisory Committee on Immunization Practices (ACIP) to address reduced effectiveness of COVID-19 monovalent vaccines during SARS-CoV-2 Omicron variant predominance (1). Initial recommendations included persons aged ≥12 years (Pfizer-BioNTech) and ≥18 years (Moderna) who had completed at least a primary series of any Food and Drug Administration-authorized or -approved monovalent vaccine ≥2 months earlier (1). On October 12, 2022, the recommendation was expanded to include children aged 5-11 years. At the time of recommendation, immunogenicity data were available from clinical trials of bivalent vaccines composed of ancestral and Omicron BA.1 strains; however, no clinical efficacy data were available. In this study, effectiveness of the bivalent (Omicron BA.4/BA.5-containing) booster formulation against symptomatic SARS-CoV-2 infection was examined using data from the Increasing Community Access to Testing (ICATT) national SARS-CoV-2 testing program.* During September 14-November 11, 2022, a total of 360,626 nucleic acid amplification tests (NAATs) performed at 9,995 retail pharmacies for adults aged ≥18 years, who reported symptoms consistent with COVID-19 at the time of testing and no immunocompromising conditions, were included in the analysis. Relative vaccine effectiveness (rVE) of a bivalent booster dose compared with that of ≥2 monovalent vaccine doses among persons for whom 2-3 months and ≥8 months had elapsed since last monovalent dose was 30% and 56% among persons aged 18-49 years, 31% and 48% among persons aged 50-64 years, and 28% and 43% among persons aged ≥65 years, respectively. Bivalent mRNA booster doses provide additional protection against symptomatic SARS-CoV-2 in immunocompetent persons who previously received monovalent vaccine only, with relative benefits increasing with time since receipt of the most recent monovalent vaccine dose. Staying up to date with COVID-19 vaccination, including getting a bivalent booster dose when eligible, is critical to maximizing protection against COVID-19 (1).


Assuntos
COVID-19 , SARS-CoV-2 , Adolescente , Adulto , Criança , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Teste para COVID-19 , Vacinas contra COVID-19 , Vacinas de mRNA , RNA Mensageiro , Estados Unidos/epidemiologia , Vacinas Combinadas
6.
MMWR Morb Mortal Wkly Rep ; 70(49): 1706-1711, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34882655

RESUMO

Immediately following the March 13, 2020 declaration of COVID-19 as a national emergency (1), the U.S. government began implementing national testing programs for epidemiologic surveillance, monitoring of frontline workers and populations at higher risk for acquiring COVID-19, and identifying and allocating limited testing resources. Effective testing supports identification of COVID-19 cases; facilitates isolation, quarantine, and timely treatment measures that limit the spread of SARS-CoV-2 (the virus that causes COVID-19); and guides public health officials about the incidence of COVID-19 in a community. A White House Joint Task Force, co-led by the Department of Health and Human Services (HHS) and the Federal Emergency Management Agency (FEMA), created the Community-Based Testing Sites (CBTS) program working with state and local partners (2). This report describes the timeline, services delivered, and scope of the CBTS program. During March 19, 2020-April 11, 2021, the CBTS program conducted 11,661,923 SARS-CoV-2 tests at 8,319 locations across the United States and its territories, including 402,223 (3.5%) administered through Drive-Through Testing, 10,129,142 (86.9%) through Pharmacies+ Testing, and 1,130,558 (9.7%) through Surge Testing programs. Tests administered through the CBTS program yielded 1,176,959 (10.1%) positive results for SARS-CoV-2. Among tested persons with available race data,* positive test results were highest among American Indian or Alaska Native (14.1%) and Black persons (10.4%) and lowest among White persons (9.9%), Asian persons (7.3%), and Native Hawaiian or Other Pacific Islanders (6.4%). Among persons with reported ethnicity, 25.3% were Hispanic, 15.9% of whom received a positive test result. Overall, 82.0% of test results were returned within 2 days, but the percentage of test results returned within 2 days was as low as 40.7% in July 2020 and 59.3% in December 2020 during peak testing periods. Strong partnerships enabled a rapid coordinated response to establish the federally supported CBTS program to improve access to no-charge diagnostic testing, including for frontline workers, symptomatic persons and close contacts, and persons living in high-prevalence areas. In April 2021, the CBTS Pharmacies+ Testing and Surge Testing programs were expanded into the Increasing Community Access to Testing (ICATT) program. As of November 12, 2021, the CBTS and ICATT programs conducted approximately 26.6 million tests with approximately 10,000 active testing sites. Although the CBTS program represented a relatively small portion of overall U.S. SARS-CoV-2 testing, with its successful partnerships and adaptability, the CBTS program serves as a model to guide current community-based screening, surveillance, and disease control programs, and responses to future public health emergencies.


Assuntos
Teste para COVID-19/estatística & dados numéricos , COVID-19/diagnóstico , Serviços de Saúde Comunitária/organização & administração , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Comportamento Cooperativo , Feminino , Acesso aos Serviços de Saúde , Necessidades e Demandas de Serviços de Saúde , Humanos , Relações Interinstitucionais , Masculino , Área Carente de Assistência Médica , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Estados Unidos/epidemiologia , Adulto Jovem
7.
J Exp Med ; 218(4)2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33544838

RESUMO

Yellow fever virus (YFV) live attenuated vaccine can, in rare cases, cause life-threatening disease, typically in patients with no previous history of severe viral illness. Autosomal recessive (AR) complete IFNAR1 deficiency was reported in one 12-yr-old patient. Here, we studied seven other previously healthy patients aged 13 to 80 yr with unexplained life-threatening YFV vaccine-associated disease. One 13-yr-old patient had AR complete IFNAR2 deficiency. Three other patients vaccinated at the ages of 47, 57, and 64 yr had high titers of circulating auto-Abs against at least 14 of the 17 individual type I IFNs. These antibodies were recently shown to underlie at least 10% of cases of life-threatening COVID-19 pneumonia. The auto-Abs were neutralizing in vitro, blocking the protective effect of IFN-α2 against YFV vaccine strains. AR IFNAR1 or IFNAR2 deficiency and neutralizing auto-Abs against type I IFNs thus accounted for more than half the cases of life-threatening YFV vaccine-associated disease studied here. Previously healthy subjects could be tested for both predispositions before anti-YFV vaccination.


Assuntos
Anticorpos Neutralizantes/imunologia , Autoanticorpos/imunologia , Doenças Autoimunes , COVID-19 , Doenças Genéticas Inatas , Interferon-alfa , Receptor de Interferon alfa e beta , SARS-CoV-2 , Vacina contra Febre Amarela , Vírus da Febre Amarela , Adolescente , Adulto , Idoso , Doenças Autoimunes/genética , Doenças Autoimunes/imunologia , COVID-19/genética , COVID-19/imunologia , Feminino , Doenças Genéticas Inatas/genética , Doenças Genéticas Inatas/imunologia , Células HEK293 , Humanos , Interferon-alfa/genética , Interferon-alfa/imunologia , Masculino , Pessoa de Meia-Idade , Receptor de Interferon alfa e beta/deficiência , Receptor de Interferon alfa e beta/imunologia , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Vacinas Atenuadas/genética , Vacinas Atenuadas/imunologia , Vacina contra Febre Amarela/efeitos adversos , Vacina contra Febre Amarela/genética , Vacina contra Febre Amarela/imunologia , Vírus da Febre Amarela/genética , Vírus da Febre Amarela/imunologia
8.
Appl Opt ; 60(1): 98-108, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33362084

RESUMO

An optical parametric oscillator (OPO) is developed and characterized for the simultaneous generation of ultraviolet (UV) and near-UV nanosecond laser pulses for the single-shot Rayleigh scattering and planar laser-induced-fluorescence (PLIF) imaging of methylidyne (CH) and nitric oxide (NO) in turbulent flames. The OPO is pumped by a multichannel, 8-pulse Nd:YAG laser cluster that produces up to 225 mJ/pulse at 355 nm with pulse spacing of 100 µs. The pulsed OPO has a conversion efficiency of 9.6% to the signal wavelength of ∼430nm when pumped by the multimode laser. Second harmonic conversion of the signal, with 3.8% efficiency, is used for the electronic excitation of the A-X (1,0) band of NO at ∼215nm, while the residual signal at 430 nm is used for direct excitation of the A-X (0,0) band of the CH radical and elastic Rayleigh scattering. The section of the OPO signal wavelength for simultaneous CH and NO PLIF imaging is performed with consideration of the pulse energy, interference from the reactant and product species, and the fluorescence signal intensity. The excitation wavelengths of 430.7 nm and 215.35 nm are studied in a laminar, premixed CH4-H2-NH3-air flame. Single-shot CH and NO PLIF and Rayleigh scatter imaging is demonstrated in a turbulent CH4-H2-NH3 diffusion flame using a high-speed intensified CMOS camera. Analysis of the complementary Rayleigh scattering and CH and NO PLIF enables identification and quantification of the high-temperature flame layers, the combustion product zones, and the fuel-jet core. Considerations for extension to simultaneous, 10-kHz-rate acquisition are discussed.

9.
Opt Express ; 28(25): 37811-37826, 2020 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-33379609

RESUMO

In this work, a variable-pulse-oscillator is developed and coupled with a burst-mode amplifier for generation of high-energy laser pulses with width of 100 ps to 1 ms and near-Gaussian temporal pulse shape. Pulse energy as high as 600 mJ is demonstrated at 1064 nm, with a super-Gaussian spatial profile and beam quality as good as 1.6 times the diffraction limit. A time-dependent pulse amplification model is developed and is in general agreement with experimentally measured values of output pulse energy and temporal pulse shape of the amplified pulses. Key performance parameters (pulse energy, temporal pulse shape, and spatial beam profile and quality) are analyzed as a function of pulse width across seven orders of magnitude. Additionally, the model is used to elucidate deviations between the simulated and experimental data, showing that the relationship between pulse width and output pulse energy is dominated by the variable-pulse-width oscillator performance, not the burst-mode amplifier.

10.
J Clin Microbiol ; 57(8)2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31142608

RESUMO

Quality standards as part of an effective quality management system (QMS) are the cornerstone for generating high-quality test results. Next-generation sequencing (NGS) has the potential to improve both clinical diagnostics and public health surveillance efforts in multiple areas, including infectious diseases. However, the laboratories adopting NGS methods face significant challenges due to the complex and modular process design. This document summarizes the first phase of quality system guidance developed by the Centers for Disease Control and Prevention (CDC) NGS Quality Workgroup. The quality system essentials of personnel, equipment, and process management (quality control and validation) were prioritized based on a risk assessment using information gathered from participating CDC laboratories. Here, we present a prioritized QMS framework, including procedures and documentation tools, to assist laboratory implementation and maintenance of quality practices for NGS workflows.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala/instrumentação , Laboratórios/normas , Saúde Pública/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Guias como Assunto , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/normas , Saúde Pública/normas , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Inquéritos e Questionários , Fluxo de Trabalho
11.
Opt Lett ; 43(5): 1115-1118, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29489807

RESUMO

Planar laser-induced fluorescence (PLIF) of hydroxyl (OH) and formaldehyde (CH2O) radicals was performed alongside stereo particle image velocimetry (PIV) at a 20 kHz repetition rate in a highly turbulent Bunsen flame. A dual-pulse burst-mode laser generated envelopes of 532 nm pulse pairs for PIV as well as a pair of 355 nm pulses, the first of which was used for CH2O PLIF. A diode-pumped solid-state Nd:YAG/dye laser system produced the excitation beam for the OH PLIF. The combined diagnostics produced simultaneous, temporally resolved two-dimensional fields of OH and CH2O and two-dimensional, three-component velocity fields, facilitating the observation of the interaction of fluid dynamics with flame fronts and preheat layers. The high-fidelity data acquired surpass the previous state of the art and demonstrate dual-pulse burst-mode laser technology with the ability to provide pulse pairs at both 532 and 355 nm with sufficient energy for scattering and fluorescence measurement at 20 kHz.

12.
Appl Opt ; 56(21): 6029-6034, 2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-29047927

RESUMO

A fiber-coupled, hyperspectral imaging sensor (HSIS) ranging from ultraviolet (UV) to short-wavelength-infrared (SWIR) wavelengths is developed for remote detection of planar [two-dimensional (2D)], spectrally resolved flame emission. The key component of the sensor is a dimension-reduction 2D-to-1D (one-dimensional) fiber-optic array that contains 1024 fibers and features high-UV optical transmission (>30% transmission at 310-340 nm, >90% at 340-2000 nm), wide operational wavelengths (300-2400 nm), and a compact and robust design (full length <5 cm). The flame-emission signals are transmitted to the remote HSIS through a 3-m-long, UV-grade, imaging fiber bundle that consists of 30,000 single-mode fibers. The design of the 2D-to-1D fiber array, the fiber-characterization process, and the sensor development are discussed in detail. 2D spectrally resolved measurements of CH*, OH*, and C2* distribution are made in premixed laminar flames. Improved chemiluminescence-based fuel/air ratio measurements using spectrally resolved detection are demonstrated. The results of the current study indicate that implementation of fiber-coupled HSIS is feasible in practical gas-turbine-engine test facilities with limited optical access.

13.
Opt Lett ; 42(18): 3678-3681, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28914931

RESUMO

Two-dimensional (2D) Raman scattering at 10 kHz in non-reacting flow mixtures is demonstrated by employing a burst-mode laser with a long-duration pulse of about 70 ns and pulse energy of about 750 mJ at 532 nm. To avoid optical breakdown, the pulse width of the laser was varied in the range of 10-1000 ns. The effects of pulse shape, pulse energy, and harmonic conversion on 2D measurements are also studied. The applications of high-speed, single-shot, 2D imaging of CH4 and H2 jets in N2 at elevated pressures are demonstrated. In addition, the scalar dissipation rate of CH4 in N2 at 20 bar is determined, and multi-dimensional, multi-species, high-speed imaging of flows at elevated pressures is demonstrated.

14.
Influenza Other Respir Viruses ; 11(3): 289-297, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28207986

RESUMO

BACKGROUND: Detections of influenza A subtype-specific antibody responses are often complicated by the presence of cross-reactive antibodies. We developed two novel multiplex platforms for antibody detection. The multiplexed magnetic fluorescence microsphere immunoassay (MAGPIX) is a high-throughput laboratory-based assay. Chembio Dual Path Platform (DPP) is a portable and rapid test that could be used in the field. METHODS: Twelve recombinant globular head domain hemagglutinin (GH HA1) antigens from A(H1N1)pdm09 (pH1N1), A(H2N2), A(H3N2), A(H5N1), A(H7N9), A(H9N2), A(H13N9), B/Victoria lineage, B/Yamagata lineage viruses, and protein A control were used. Human sera from U.S. residents either vaccinated (with H5N1 or pH1N1) or infected with pH1N1 influenza viruses and sera from live bird market workers in Bangladesh (BDPW) were evaluated. GH HA1 antigens and serum adsorption using full ectodomain recombinant hemagglutinins from A(pH1N1) and A(H3N2) were introduced into the platforms to reduce cross-reactivity. RESULTS: Serum adsorption reduced cross-reactivity to novel subtype HAs. Compared to traditional hemagglutination inhibition or microneutralization assays, when serum adsorption and the highest fold rise in signals were used to determine positivity, the correct subtype-specific responses were identified in 86%-100% of U.S. residents exposed to influenza antigens through vaccination or infection (N=49). For detection of H5N1-specific antibodies in sera collected from BDPW, H5 sensitivity was 100% (six of six) for MAGPIX, 83% (five of six) for DPP, H5 specificity was 100% (15/15), and cross-reactivity against other subtype was 0% (zero of six) for both platforms. CONCLUSION: MAGPIX and DPP platforms can be utilized for high-throughput and in-field detection of novel influenza virus infections.


Assuntos
Anticorpos Antivirais/sangue , Glicoproteínas de Hemaglutininação de Vírus da Influenza/imunologia , Ensaios de Triagem em Larga Escala/métodos , Imunoensaio/métodos , Vírus da Influenza A/imunologia , Influenza Humana/sangue , Animais , Anticorpos Antivirais/imunologia , Bangladesh , Doenças das Aves/sangue , Doenças das Aves/virologia , Aves , Reações Cruzadas , Humanos , Vírus da Influenza A/classificação , Vírus da Influenza A/isolamento & purificação , Influenza Humana/virologia , Especificidade da Espécie
15.
Opt Lett ; 42(1): 53-56, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28059176

RESUMO

See-through-wall coherent microwave scattering from resonance-enhanced multiphoton ionization (REMPI) for rotational temperature measurements of molecular oxygen has been developed and demonstrated in a flow reactor at atmospheric pressure. Through limited, single-ended optical access, a laser beam was focused to generate local ionization of molecular oxygen in a heated quartz flow reactor enclosed by ceramic heating elements. Coherent microwaves were transmitted, and the subsequent scattering off the laser-induced plasma was received, through the optically opaque ceramic heater walls and used to acquire rotational spectra of molecular oxygen and to determine temperature. Both axial and radial air-temperature profiles were obtained in the flow reactor with an accuracy of ±20 K⁢(±5%). The experimental results show good agreement with a steady-state computational heat transfer model. This technique shows great potential for non-invasive, high-fidelity measurement of spatially localized temperature and radical species concentration in combustion kinetic experiments and confined combustors constructed of advanced ceramic materials in which limited or non-existing optical access hinders usage of conventional optical diagnostic techniques to quantify thermal non-uniformity.

16.
J Virol Methods ; 243: 61-67, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28108183

RESUMO

Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex®, and ForteBio® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections.


Assuntos
Anticorpos Antivirais/sangue , Glicoproteínas de Hemaglutininação de Vírus da Influenza/imunologia , Ensaios de Triagem em Larga Escala/métodos , Influenza Humana/epidemiologia , Influenza Humana/virologia , Testes Sorológicos/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
17.
Opt Express ; 24(22): 24971-24979, 2016 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-27828437

RESUMO

Two-dimensional gas-phase coherent anti-Stokes Raman scattering (2D-CARS) thermometry is demonstrated at 1 kHz in a heated jet. A hybrid femtosecond/picosecond CARS configuration is used in a two-beam phase-matching arrangement with a 100-femtosecond pump/Stokes pulse and a 107-picosecond probe pulse. The femtosecond pulse is generated using a mode-locked oscillator and regenerative amplifier that is synchronized to a separate picosecond oscillator and burst-mode amplifier. The CARS signal is spectrally dispersed in a custom imaging spectrometer and detected using a high-speed camera with image intensifier. 1-kHz, single-shot planar measurements at room temperature exhibit error of 2.6% and shot-to-shot variations of 2.6%. The spatial variation in measured temperature is 9.4%. 2D-CARS temperature measurements are demonstrated in a heated O2 jet to capture the spatiotemporal evolution of the temperature field.

18.
Proc Natl Acad Sci U S A ; 112(10): 3050-5, 2015 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-25713354

RESUMO

CD8 T cells are a potent tool for eliminating intracellular pathogens and tumor cells. Thus, eliciting robust CD8 T-cell immunity is the basis for many vaccines under development. However, the relationship between antigen load and the magnitude of the CD8 T-cell response is not well-described in a human immune response. Here we address this issue by quantifying viral load and the CD8 T-cell response in a cohort of 80 individuals immunized with the live attenuated yellow fever vaccine (YFV-17D) by sampling peripheral blood at days 0, 1, 2, 3, 5, 7, 9, 11, 14, 30, and 90. When the virus load was below a threshold (peak virus load < 225 genomes per mL, or integrated virus load < 400 genome days per mL), the magnitude of the CD8 T-cell response correlated strongly with the virus load (R(2) ∼ 0.63). As the virus load increased above this threshold, the magnitude of the CD8 T-cell responses saturated. Recent advances in CD8 T-cell-based vaccines have focused on replication-incompetent or single-cycle vectors. However, these approaches deliver relatively limited amounts of antigen after immunization. Our results highlight the requirement that T-cell-based vaccines should deliver sufficient antigen during the initial period of the immune response to elicit a large number of CD8 T cells that may be needed for protection.


Assuntos
Linfócitos T CD8-Positivos/imunologia , Carga Viral , Vacina contra Febre Amarela/imunologia , Estudos de Coortes , Perfilação da Expressão Gênica , Humanos , Vírus da Febre Amarela/genética , Vírus da Febre Amarela/imunologia , Vírus da Febre Amarela/isolamento & purificação
19.
J Psychosom Res ; 78(3): 199-204, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25258356

RESUMO

OBJECTIVE: The aim of this study is to describe the clinical phenotype of alcohol use disorder (AUD) treatment-seeking patients with Roux-en-Y Gastric Bypass Surgery (RYGB) history; and to compare it to AUD obese non-RYGB controls. METHODS: Retrospective study of electronic medical records for all patients 30-60years treated at the Mayo Clinic Addiction Treatment Program, between June, 2004 and July, 2012. Comparisons were performed with consumption patterns pre-RYGB and at time of treatment; excluding patients with AUD treatments pre-RYGB. RESULTS: Forty-one out of 823 patients had a RYGB history (4.9%); 122 controls were selected. Compared to controls, the RYGB group had significantly more females [n=29 (70.7%) vs. n=35 (28.7%) p<0.0001]; and met AUD criteria at a significantly earlier age (19.1±0.4 vs. 25.0±1years old, p=0.002). On average, RYGB patients reported resuming alcohol consumption 1.4±0.2years post-surgery, meeting criteria for AUD at 3.1±0.5years and seeking treatment at 5.4±0.3years postoperatively. Pre-surgical drinks per day were significantly fewer compared to post-surgical consumption [2.5±0.4 vs. 8.1±1.3, p=0.009]. Prior to admission, RYGB patients reported fewer drinking days per week vs. controls (4.7±0.3 vs. 5.5±1.8days, p=0.02). Neither RYGB, gender, age nor BMI was associated with differential drinking patterns. CONCLUSION: The results of this study suggest that some patients develop progressive AUD several years following RYGB. This observation has important clinical implications, calling for AUD-preventive measures following RYGB. Further large-scale longitudinal studies are needed to clarify the association between RYGB and AUD onset.


Assuntos
Consumo de Bebidas Alcoólicas/epidemiologia , Alcoolismo/complicações , Derivação Gástrica , Obesidade/psicologia , Obesidade/cirurgia , Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/psicologia , Alcoolismo/diagnóstico , Progressão da Doença , Registros Eletrônicos de Saúde , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Período Pós-Operatório , Estudos Retrospectivos
20.
Artigo em Inglês | MEDLINE | ID: mdl-27990325

RESUMO

Novel data streams (NDS), such as web search data or social media updates, hold promise for enhancing the capabilities of public health surveillance. In this paper, we outline a conceptual framework for integrating NDS into current public health surveillance. Our approach focuses on two key questions: What are the opportunities for using NDS and what are the minimal tests of validity and utility that must be applied when using NDS? Identifying these opportunities will necessitate the involvement of public health authorities and an appreciation of the diversity of objectives and scales across agencies at different levels (local, state, national, international). We present the case that clearly articulating surveillance objectives and systematically evaluating NDS and comparing the performance of NDS to existing surveillance data and alternative NDS data is critical and has not sufficiently been addressed in many applications of NDS currently in the literature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...